Thursday, April 16, 2020

The future of consumer muscle O2 monitoring - trainer derived MLSS?

The recent demise of the Humon Hex on top of the prior exit of BSX Athletics from the field of muscle O2 saturation monitoring makes this an appropriate time to talk about several issues.
  • Why can't these companies turn a promising idea into a successful ongoing business?
  • What choices do we have left in monitoring muscle O2?
  • Is there still a role of this technology in the consumer/amateur exercise field?

I can only conjecture on the first question, but it may have something to do with my whole point in starting this blog many years ago.  After reading the forums on the Moxy website, I was appalled by the lack of hard fact and abundance of pure anecdote.  Wild claims were made for all of these devices (read my review of the Hex for example) that although they may have a shred of theoretical logic, most are just plain nonsense.  Therefore consumers buying these units will ultimately be disappointed by the promise of unrealistic expectations.  No - they don't help in recovery, effort modulation (well, without a proper ramp and data analysis), optimize your workout routine!

Believe me, I am not "trying to kick a dog while they are down" or an "I told you so".  But, I did have an honest conversation with the Humon folks before launch and respectfully asked them to be honest about the claims.  So if you were a buyer and hoped for the above features, you would have been very disappointed.

What is still available now?
Unless you can get a "new old stock" or used BSX/Hex on Ebay, the only option is the Moxy.  The price is just over $800 for 1 sensor.  They have been around the longest and have a good reputation for standing behind their product.  But, the device has not seen a major hardware revision (ever?) and is still a clunky box.  Given that they are probably struggling to stay in business, I understand the lack of funding for a redesign.

Now the key question - Is there any (major) role for the sensor in current athletic training.
The answer is yes - there are now enough studies showing that identifying the "breakpoint" in VL or RF desaturation that occurs with increasing exercise effort, can be used as a surrogate for a MLSS, RCP, VT2, LT2 intensity.  The question is - is it worth the cost?  Alternatives include buying a lactate meter and strips (about $450), then performing a series of intervals to generate a lactate curve.  Advantages of a lactate test is that you may be able to also get a LT1 intensity to help with zone 1 demarcation.  However, the issues with lactate testing are many and the result may not be precise.  Other modalities to get a VT2/LT2 include gas exchange testing (about $150 for my local center), and doing an FTP test which we have covered.  
The choice is yours and they all have their merits.  But the Moxy price just does not seem to make sense for what you are buying (forget the hype).

If someone came up with a unit in the $150 price range to calculate your MLSS, that would be a good cost:benefit ratio.  In fact, since you really need a smart trainer with power monitoring (or a treadmill) to do this accurately, it could be offered as an inexpensive add on for the trainer purchase.

In the past, I have struggled to make ramps "work".  It is very difficult to both cycle hard, keep an eye on power as well as ramp time.  The appearance of affordable smart trainer has made doing a ramp a much different experience.  With a feedback controlled trainer using Zwift (or equivilant) all you need to do is pedal and the rest is done for you.  That makes doing a desaturation ramp easy.  Below is another example with both the RF and VL:

The following data is an example of how trainers ans O2 sensor tech can work together.  
The test subject is myself (VO2 max 55 ml/kg/min and a RCP/LT2 power of 275+- watts).  
The ramp was done on an Elite Suito with my Assomia Duo pedals providing the cycling power data.  The Humon Hex was on my L RF and the BSX Insight on my R VL.  Thanks to Zwift, it was easy to create an incremental ramp starting at 100w, with an increase of 10 watts per minute up to 310 watts (almost my maximum which is near 330w).

The first plot is the Cyclinganalytics.com power curve:


  • The cadence is the same throughout and the power rises quite smoothly.  Even though it's set for 10 watts per minute, Zwift is able to raise resistance continuously, so no abrupt transition occurs.

The Data:
We will need to plot this out officially in order to interpolate the MLSS/RCP from the SmO2 data.
For example, let's say the breakpoint occurs at 1080 seconds into the test, what is the equivilant average wattage (intensity) at that point?

Here is an Excel plot (with regression formula):
 According to the formula, at a time of 1080 seconds, wattage was 278.


Now we look at the Vastus desaturation curve with calculated HHb.  Remember the VL shows a plateau starting at the MLSS as opposed to the abrupt rise seen in the RF behavior.


And the Rectus Femoris:
Here we are looking for the departure of a linear desaturation (increase in HHb), with an upward change in slope:

The lines are drawn in and show the following:
  • VL plateau begins at about 1080 seconds.
  • RF curve slope steepens at about the same time, 1080 seconds.
  • Power vs time formula gives us a derived wattage of 278 with a time (x) of 1080 seconds.
  • The curve shift needed given the ramp speed (10w/min) is about 3 watts.
  • Final MLSS/RCP is about 275 watts.  Very close to what my previous gas exchange and lactate testing showed.

Although this seems easy to do, it is not as simple as one may think.
Some potential limitations and source of error (yes, I've seem them all):
  • Wrong sensor position - such as between the RF and VL area.
  • Poor control of incremental power rise (common).  In the days before a smart trainer, this would be very difficult to pull off and I rarely got a good looking curve.
  • Difficulty in plots and graphs.  Although not at the rocket science level, one does need some basic math and spreadsheet skills.

Final thoughts and wish list:
  • Is this the end of the consumer muscle O2 story?  I hope not.  It still is a viable alternative to measure RCP/MLSS breakpoints, which is helpful in setting up your zone 3 training intensity.  Yes, lactate testing can be done, if you are willing to jump those hurdles.  Yes, FTP can be done but is exhausting and can vary in accuracy.
  • Given the interdependence of both accurate ramp intensity structure with muscle desaturation curves, it makes sense that either trainer manufacturers and/or new startups in sensor tech build an integrated framework around this typical usage scenario.  Take the data plotting out of the picture - simply put the sensor on, start a ramp and get your result.  BSX started with this but it was before smart trainer availability.
  • The sensor vendors need to abandon the hype and hypothetical claims.  They should rely on the solid foundation of the VL or RF breakpoint as a means of RCP/MLSS identification.  Having one solid usage scenario is fine, we don't need five.
  • Price points needs to be reasonable.  The hardware costs can't be much higher than a Polar OH1.  Bundling this with many smart trainers should enter into the product volume calculations.
  • And here you have the published evidence: 
  • Combining NIRS and DFA a1 for critical intensity estimation  

 See also:
 
 


 

Saturday, March 14, 2020

Intelligent training through the Pandemic

Although the news is full of opinion and advice on how to survive the new few months, I wanted to review some literature as well as personal recommendations on what we should be doing until the global coronavirus pandemic is under control and life is back to normal.  The strategy I would take would revolve around both the twin goals of maintaining fitness without compromising the immune system.  
I won't get into social distancing, but it is a no-brainer to avoid crowded gyms, training facilities or cycling classes.  Limited outdoor activity with a few people is possibly ok, especially if you are in a strong UV light environment. 

Before going over some recommendations from a recent publication, let's examine what we are trying to achieve.  Since races are cancelled, there is little reason to be at peak fitness at this time.  Letting go of that training goal is extremely important right now, since we will see shortly that many of the factors that suppress immunity are involved in reaching peak fitness.  That leaves us two options, letting things slide or trying to maintain at a reasonable level.  Either are reasonable, but the strategy of maintaining is most appealing to me.

The following data was obtained from a recent review of immune function and exercise.

Here are the factors involved:

Prolonged high intensity:
In athletes under heavy training both innate and acquired immunity are often observed to decrease transiently during the recovery period after prolonged heavy exertion (≥90 min); typically of the order 15–70%
Periods of overreaching and longer term maladaptation (coined ‘overtraining’),in particular, have been shown to decrease immunity
But:
Empirical evidence,albeit in a small number of athletes, indicates that international athletes suffer fewer not greater URI episodes than national-level athletes and that URI incidence correlates negatively with training load,viz.‘the less sick the more the athlete can train’. However, there may be genetic and/or modifiable behavioural factors that account for why international athletes succumb to fewer URI’s than national-level  athletes during  high-volume training
In other words, we don't all ride (or have the physiology) like Lance (or Froome etc) - which we all realize.

Recent evidence lends some support for this notion by showing that gene polymorphisms for the high expression of pro-inflammatory cytokines predict URI in highly trained athletes 
The presence of a huge support staff of therapists, logistic personnel and planned nutrition for the pros, is also a mitigating factor to combat high intensity - which us amateurs do not have.


Sleep disruption or deficiency:
Chronic sleep disturbance and disruption to the normal circadian rhythm (e.g. shiftwork) are associated with inflammation and desynchronisation of rhythmic immune variables; likely contributing to increased risk of infection, cardiovascular disease and cancer in long-term shift workers
In other studies, those sleeping <6 h per night and those with sleep efficiency <92% the chance of developing a common cold after intra-nasal inoculation with rhinovirus increased∼4–5 times
Preliminary laboratory work shows increased muscular performance with∼2 hours additional sleep each night

Stress:
As might be expected, research from the field of psycho-neuro-immunology indicates that chronic high stress impairs the immune response to challenge
So keep stress down:

The Environment:
Cold weather
A popular belief held by many athletes is that breathing cold, dry air and getting a‘chill’ through cooling of the skin cause the‘common cold’. Although controversial, some evidence shows that peripheral cooling of the nose and upper airways (and even the feet)can increase URI symptoms; indeed, peripheral cooling may inhibit immune cell trafficking and create a suitable local environment for viral replication(Johnson & Eccles,2005). In support of this contention, recent research provides the missing piece of the jig-saw by showing that the human rhinovirus, a common cold causing virus, replicates more robustly at cooler temperatures found in the nasal cavity (33–35°C) (Foxman, Storer, Vanaja, Levchenko, &Iwasaki,2016). The temperature-dependent rhino-virus amplification is largely a result of host cell anti-viral  restriction  mechanisms  operating  more effectively at 37°C than at 33°C (Foxman et al.,2016). This research may at last provide an explanation for  why  cold  ambient  conditions  often precede outbreaks of URIs such as the common cold(Mäkinen et al.,2009). With this in mind, wherever possible, athletes are recommended to take extra precautions to avoid breathing large volumes of cold, dry air when training and competing in the winter.
At the time of this writing, it is unclear if coronavirus behavior is related to cooler conditions or not.  

Altitude:
One emerging trend from the literature is that immunity and host defence are typically decreased in studies where athletes complete live-high train-high or live-high train-low altitude training methods but not in studies  involving  intermittent  hypoxic  training 
 Long distance travel:
Studies are required to determine whether the increase in URI symptoms with long-haul travel is due to hypoxia-induced immune alterations, increased exposure to pathogens in the aircraft cabin, or some other mechanism. It is quite conceivable that the increase in psychological stress, anxiety and travel fatigue associated with long-haul travel to training camps and competitions may increase URI. For example, athletes may experience anxiety related to fear of flying, flight delays and baggage issues; they may also experience travel fatigue related to sleep loss and jet lag. 

Diet and Carbohydrate use:
Despite much interest and fervour amongst exercise immunologists, promising early findings demonstrating the benefits of carbohydrate sports drinks to blunt in-vitro immune impairment with heavy exercise have not been realised in studies assessing clinically relevant in-vivo immunity

But:
Paradoxically,  nutritional  strategies  currently adopted by endurance athletes, including training-low- and sleeping-low-carbohydrate (Marquet et al.,2016), may benefit training adaptations and performance at the expense of immunity 

Vitamin D is a familiar topic in my field of endocrinology.  Although having your Vit D level in a "normal range" is quite desirable, the evidence on immune function is very complex and often contradictory.  My recommendation is to keep the Vit D level between 40-80 ng/ml, and don't go by a blanket supplement dose - there are huge differences in personal requirements - get levels if possible.

And the final recs:
My final comments:
  • Take advantage of polarized training - 90% or more of your time spent in zone 1, otherwise brief HIT/SIT above VT2/MLSS.  Do not spend much, if any time in zone 2 or at MLSS.  Since we are aiming to maintain fitness with no impact on immunity, there is little advantage to going above this type of program.  If you have a low artifact HRV recording, consider following DFA a1 and make sure it is above .7 for the bulk of your training.  It is a marker of neuro cardiovascular stress, values of .5 and below correspond to a stress response.
  • Do not restrict carbs during any day that you train in zone 3.  Doing an hour of zone 1 while fasting seems fine, but could lead to exaggerated stress hormone elevation in zone 3.
  • Get extra sleep.  If you can't, do not train in zone 3.
  • Hand hygiene and the other advice will be helpful as well.
  • Do not do group indoors exercise class!!!

Tuesday, March 3, 2020

Recent article on DFA a1 and Zone 1 demarcation

Over the past year, several posts have been presented looking at the relationship of certain HRV parameters and the first ventilatory threshold.  I decided to take a closer look at the usage of DFA a1 as a zone 1 marker for exercise prescription and write up it up as a case report .  As part of the investigation, incremental exercise ramps were done with and without beta blocker therapy.  The use of beta blockade allows us to change the stroke volume x heart rate proportions, without affecting the end result, the cardiac output.  One of my questions was whether absolute heart rate was the prime driver of DFA a1 change or was it cycling power/VO2.
The investigation used many of the devices discussed over the past years including muscle O2 as an index of A-V O2 extraction, Hexoskin for artifact free HRV recording as well as ventilation rates. 
Here is the link to full text and the abstract is below:


The introduction and discussion will be instructive from the viewpoint of the various pitfalls of LT1/VT1 determination for zone 1 limitation.  The use of beta blockade was quite interesting to explore.  For any of the readers out there who are athletes on beta blocker therapy, this should reassure you that no major impairment of endurance performance should occur.

In addition to the data presented in the above paper, I would like to add another piece of the puzzle.  Although I did 10 minute intervals in the published study, looking for stability of the DFA a1, longer cycling sessions near VT1 were not done. To address what happens with prolonged cycling just below VT1 for about 80 minutes of constant power cycling was done.

Below is a trace of DFA a1 over about 80 minutes, recorded with the Hexoskin (no artifacts), with DFA a1 readings every 7 minutes or so (raw data to the left).  The power was fixed at 8 watts below VT1 by the Elite Suito trainer.

  • What this is showing is that as long as power is below VT1 (by 8w - clamped by the trainer), DFA a1 stays above .6 (orange).  Even though there is some minimal cardiac drift in heart rate past the 40 minute mark (blue), DFA a1 remains quite stable at .6 to .7.  
  • For my purposes, this is comforting to see.  Power just below my VT1 does not lead to demonstrable suppression of DFA a1 despite continuous effort for long duration.  Since the goal is to spend large amounts of time in zone 1, undue neuro-vascular stress is undesirable.
  • Further testing with slightly higher power would also be interesting, looking for progressive decline, for example at 10 watts above VT1.  


Heart rate variability during dynamic exercise

Friday, February 7, 2020

Smart trainer usage in physiologic testing and interval training

Over the past few years numerous cycling ramps and intervals have been presented in this blog.  About 6 weeks ago, I attempted to do a ramp on my "dumb", fixed resistance turbo trainer consisting of 30 watts per minute rise, beginning at 100 watts.  Despite my long standing familiarity in performing ramps, there was major difficulty in ratcheting up the power evenly, especially at the higher values.  This was related to several reasons including the need to constantly watch the average lap power (each 1 minute) as well as pressing the lap button (disrupting my power flow) and shifting gears.  Sure, doing a series of 5 minute ramps with 25-30 watt differential is doable, but 20 watt per minute is not going to be easy and 10 watt per minute may not be possible.  I had previously heard of "smart" trainers that would automatically change resistance and "clamp" your power within a narrow range.  This seems ideal in theory, and in fact most physiology laboratories utilize similar equipment.  Here is an example of a lab grade cycle ergometer:


This particular model is about $3000.  Forget the price a moment, does this look comfortable to spend time on?  The pedals have no clips and the upright body position could lead to false ergonomics.  We just don't ride this way!  So if you did testing on this bike, the results don't necessarily translate to real world riding on your own bike. 

Can we do as well from the "watt clamping" standpoint with a smart trainer?  
Let's explore that question.

Before looking at what a smart trainer can do, a look at manually doing a ramp on a fixed resistance trainer is important.  Although I've done them before, it is very difficult to keep steady power, watch your interval time, shift gears and hit the lap buttons to do it well.  Here is a typical attempt on my part, of a 30 watt per minute ramp (20 watts per minute would be much more difficult):
Although I did ok on the cadence, I needed to constantly shift gears, which caused difficulty maintaining a steady power output.  Notice the very unstable power readings especially at the high wattage.

Worse, is the average watt per interval.  Here is a listing of each stage with the desired targets in red on the right:
There were substantial differences in target power, worse at the higher rates.
Coupled with the already uneven pacing pattern, the physiologic results of this session would be untrustworthy to say the least.

Can we do better with a smart trainer?

One of the more reasonably priced "smart", electronically controlled trainer options (about $800) is the Elite Suito.   If you are interested in other models, that's fine and many trainer reviews are available.  I was happy with the Elite Muin basic model I had before and decided to stick with Elite.

The Suito:
It's quiet, has great road feel (even with Powercranks) and comes already set up.  Just pull it out of the box, spread the feet and go.
The trainer needs to be controlled with software if you are interested in either physiologic testing or doing fixed power workouts.  I have tried both the Elite app as well as Zwift.  The Elite app is a no frills program for your phone or laptop.  Both apps allow you to use your own power meter, so there is no reason to rely on the less accurate trainer meter.

Here are a couple of screenshots of the Elite app, the first was the creation of a custom ramp, beginning with warmup, 100w start then 20w per minute until stopping (near exhaustion).

And a screen of custom workout choices that I designed:



  • The top workout was simply a series of 5 minute intervals at my VT1 power, plus or minus 25 watts hence - 150 then 175 then 200w.
  • The middle was a single 5 minute 269 watt interval (after a long warmup) to test some MLSS metrics.
  • The bottom was the 20 watt per minute ramp.

How did the 20 watt per minute ramp look?

Here is the Cyclinganalytics.com display:

With the 1 minute splits (the desired watts are in red on the right column):


Although the average is close to desired, it does deviate somewhat above 200 watts.
A clue to this is the rise in cadence.  


Although the trainer should reduce resistance as cadence rises, there will still be some resistance-time lag and that is probably why I was 20 watts too high at the end.  Still, the results are reasonable, and with some practice (stable cadence) could be even closer.  This is certainly better than the manually done ramp (which was 30w per minute).

Can the smart trainer maintain strict enforcement of interval power?
This was part of a series of repeats of 145, 155, 175 and 195 watts.  As indicated, the cadence and power were near perfect.  Stable cadence and square wave power were the result.

Comments on the Elite training app:
  • There is no entertainment factor, just the nuts and bolts of power/time.
  • There is some lag.  
  • If you reduce the cadence markedly (coasting), there is a dramatic increase in resistance.  I would recommend pausing the active routine and restart the program while pedaling.
  • The workout creation tool is not as intuitive as it could be.
  • The resistance during initial warmup (first 15 minutes) is higher than it should be.
  • But, once you are warmed up, the desired target power will be very close to the realtime power output.

Zwift usage:
There is ample literature on using Zwift, the erg mode option and workout creation (so I will skip that).  What I will review is my own observations and comparison to the Elite app.
However, make sure you are in erg mode when doing the test ramps and intervals.  This mode provides a clamp on power by varying the pedal resistance. A higher cadence will cause the app to lower resistance, providing the same net power output.

Zwift is partly entertainment.  The graphics of a virtual ride are excellent, there is potential real life pedaling resistance up inclines (non erg mode), you can earn points, pass virtual riders plus acquire virtual gear (for the gamers out there - think Diablo armor).

Designing workout and test protocols on Zwift is very easy.  There is a "create custom workout" option (not on the smartphone app, only the laptop/PC version).
Here is what  the workout creator looks like: 


And here is my new custom ramp of 10 watts per minute, ending at 300w:


I have not tried this yet but it's next on my list of tests to do.

Interval power stability with Zwift:
This is an example of 5 minute intervals done in Zwift that was designed to be just below, and above my MLSS:

Here I designed a set of 5 minute intervals in Zwift with a target of 261 and 276 watts:
 
Real world output result:
Looking at the pair of 5 minute intervals, the first is spot on the target and the second is only 3 watts higher (<1%)


  • There was smooth cadence and relatively stable power.

There was a tiny bit more variation with the 155, 175, 195w intervals, but they were within 1% of target power:

All in all, Zwift does a competent job of keeping your power and cadence stable in erg mode.  I did not design a 20w per minute ramp, but it can be done.

Comparison to the Elite training app:
  • There is excellent entertainment potential, great graphics and possibility for social interaction. 
  • There is less lag in resistance.  
  • If you reduce the cadence markedly (coasting), there is minimal increase in resistance.  Therefore, you can stop riding and the resistance reduces to compensate.
  • The workout creation tool is easy to use.
  • The resistance during initial warmup (first 15 minutes) is not higher than it should be.  Somehow, the Zwift app takes this into account better than Elite does.
  • There may be a bit less of interval power stability.  Since the trainer resistance does not change as quickly as using the Elite app, one can deviate more from target wattage.  The trade off is being able to pause at will without hitting any pause buttons.



Putting this into practical usage.

The 20 watt per minute ramp:
Obtaining your MLSS using a rectus femoris muscle O2 tracing should be possible with the 1 minute ramp stage process (using Elite's app).  Remember, we will need to figure out the approximate wattage at the breakpoint, then subtract about 10-15 watts due to the "response time" of VO2 change according to the article of Murias.
Here is what my data showed (from the above 1 minute per stage ramp).  Each point represents the O2 sat of the rectus femoris (per each second) over the course of the ramp.  I found the breakpoint (red line intersection), then noted the corresponding elapsed time.  Using that time marker, the average power over the past 20 sec was calculated at 290w.  Taking 15w off this figure results in a MLSS of 275w, which is very close to my historic data (and official testing):






Using the Zwift ramps above:
Although not spoken of in the literature, this is a favorite of mine to determine MLSS.
We are looking for the transition from stability of RF muscle O2 over time to a constant decline over 5 minutes.

The rectus femoris site had a similar O2 saturation breakpoint between 261 and 279 watts:

  • Somewhere between the 261 to 278w zone is the limit of stable muscle O2 sat.   
  • Potentially, with finer increments, this could be tracked down to a more narrow range.
  • Good agreement with the 20w per minute ramp.
  • Excellent target watt agreement with the custom protocol

Summary:
  • It is very difficult (near impossible) to perform a 20w per minute incremental ramp to (near) exhaustion with a reasonable degree of accuracy using a standard resistance trainer.
  • Smart trainers by virtue of their feedback properties in combination with appropriate software, have a much better chance of approaching lab grade equipment.
  • Advantages in doing so include price, ergonomics, comfort and body position specificity in both training and testing.  Using your own bike to do the testing is priceless.
  • Both the Elite training app and Zwift provide the ability to create custom training protocols and testing schemes.
  • Both apps will result in fine control of incremental resistance at a fixed cadence.
  • With the availability of reasonably priced smart trainers and control software, home physiologic testing and defined interval training are now both possible and fun to do.